cmrr: >80db @ dc to 60hz, rs=1k

input impedance: 10m 30pf nominal (80pf nominal for 500mv range) residual
reading less than 50 digits with test leads shorted.

DBM: at 600, -11.76dbm to 54.25dbm
accuracy: 0.25db + 2d (@40hz -- 20khz)
input impedance: 10m, 30pf nominal
selectable reference impedance of 4, 8, 16, 32, 50, 75, 93, 110, 125, 135, 150,
200, 250, 300, 500, 600,800, 900, 1000, 1200

AUDIBLE CONTINUITY TESTER

Audible threshold: between 20 and 200 response time < 100µS

Diode Tester

Range

Accuracy

Test Current

(Typical)

Open Circuit

Voltage

5.0000V

1%+1D

0.4mA

< 3.5 VDC

Capacitance

Range

Accuracy*

50.00nF

0.8% + 3D

500.0nF

0.8% + 3D

5.000µF

1.5% + 3D

50.00µF

2.5% + 3D

500.0µF**

3.5% + 5D

9999µF**

5.0% + 5D

*accuracies with film capacitor or better

**in manual-ranging mode, measurements not specified below 45.0µF and
450µF for 500.0µF and 9999µF ranges respectively