Amprobe AM-220 Digital-Multimeters User Manual

Page 8

Advertising
background image

4

AC VOLTAGE

Range

Accuracy

Resolution

400mV

± ( 1.5%+3 )

0.1mV

4V

± ( 1.0%+2 )

1mV

40V

10mV

400V

100mV

600V

± ( 1.5%+3 )

1V

Average sensing, calibrated to RMS of sine wave
Frequency: 40 ~ 400Hz
Overload protection: 600V DC or AC RMS
Impedance: 10MW , More than 100MW on 400mV range
DC CURRENT

Range

Accuracy

Resolution

400μA

± ( 1.2%+3 )

0.1μA

4000μA

1μA

40mA

10μA

400mA

100μA

4A

± ( 2.0%+5 )

1mA

10A

10mA

Overload protection: 0.5A/250V, 10A/250V fuse
AC CURRENT

Range

Accuracy

Resolution

400μA

± ( 1.5%+3 )

0.1μA

4000μA

1μA

40mA

10μA

400mA

100μA

4A

± ( 2.5%+5 )

1mA

10A

10mA

Average sensing, calibrated to RMS of sine wave
Frequency: 40~400Hz
Overload protection: 0.5A/250V, 10A/250V fuse

Advertising