Amprobe AM-220 Digital-Multimeters User Manual

Page 9

Advertising
background image

5

RESISTANCE

Range

Accuracy

Resolution

400W

± ( 1.0%+5 )

0.1W

4kW

1W

40kW

10W

400kW

100W

4MW

1kW

40MW

± ( 2.0%+3 )

10kW

Overload protection: 250V DC or AC RMS

CAPACITANCE

Range

Accuracy

Resolution

40nF

± ( 3.0%+10 )

10pF

400nF

± ( 2.5%+5 )

100pF

4μF

1nF

40μF

10nF

400μF

± ( 5.0%+10 )

100nF

4000μF

± ( 20.0%+20 )

1μF

Overload protection: 250V DC or AC RMS

DIODE AND AUDIBLE CONTINUITY TEST

Range

Description

Test condition

Display read approximately
forward voltage of diode

Forward DC current approx. 0.4mA
Reversed DC voltage approx. 2.8V

Built-in buzzer sounds if resistance
is less than 50W

Open circuit voltage approx. 0.5V

Overload protection: 250V DC or AC RMS