ppm

Symptoms and applicable standard

400

frontal headache, life threatening after 3hrs. Maximum concentration in flue gas
per epA and AgA.

800

dizziness, nausea, convulsions, death w/i 2-3 hrs.

1600

nausea w/i 20 min; death w/i 2-3 hrs

opERAtIoN

1. power on/off

press

•

�

to turn on and off the meter. when meter is power on, the preset alarm value and

current air temperature will be blinking on the lCd.
Meter will perform Self-Test for 15 seconds. A beep after the self test indicates that the

•

meter is ready to use.

A 25

ppm

26 C

IMpoRtANt:
it is recommended to turn on the meter in an area free of Co since high Co level may cause
failure in passing Self-Test.

2. Alarm setting

The meter alarm is preset to 25ppm to warn about possible danger.

•

User can adjust the alarm level by choosing one. The available Co gas levels: 25, 30, 35, 45,

•

50, 70, 100 and 200ppm.
Release the pushbutton to select the preferred value. The meter will return to Self-Test

•

mode in a few seconds.

3. Measurement

The meter detects the existence of Co in the environment and displays the reading in ppm.

•

it also indicates the maximum value (at lower side of the lCd) of all readings.
Reset the maximum value by pressing

•

pushbutton for two seconds in measuring mode.

4. Backlight
press

pushbutton to turn on and off the backlight.