0029 verify started, 002a verify failed – Avago Technologies 3ware SAS 9750-16i4e User Manual

Page 266

Advertising
background image

Chapter 12. Troubleshooting

254

3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.2

0029 Verify started

Event Type

Information

Cause

The 3ware RAID controller has started verifying the data integrity of a unit.
The verification functions for different RAID levels are as follows:
•

Single.

Verify = Media scan

•

RAID 0.

Verify = Media scan

•

RAID 1 and 10.

Verify = Comparison of mirror sides

•

RAID 5, 6, and 50.

Verify = Comparison of parity data with user data

Action

Allow verify to complete to identify any possible data integrity issues.

See Also

For information on scheduling a verify process, see “Scheduling Background
Tasks” on page 163.
For information on verification of a unit, see “About
Verification” on page 149
.

002A Verify failed

Event Type

Error

Cause

Verification of a unit has terminated with an error. For each RAID level being
verified, this may mean:

•

Single.

A single drive returned an error, possibly because of a media

defect.

•

RAID 0.

A single drive returned an error, possibly because of a media

defect.

•

RAID 1 and 10.

One side of the mirror does not equal the other side.

•

RAID 5, 6, and 50.

The parity data does not equal the user data.

For any RAID type, the most likely cause of the error is a grown defect in the
drive. For out-of-synchronization mirrors or parity, the error could be caused
by improper shutdown of the unit. This possibility applies to RAID 1, 5, 6, 10,
and 50.

Advertising