Controller Installation (Standard)

2-14

AcceleRAID 150 Installation Guide

12. Enable termination power to all the disk drives (usually there is a

jumper on the drive). See your device documentation for instructions
on how to set your particular disk drive’s termination power and
configuration options.

☛

Note

The supported SCSI drive types include Ultra2 SCSI
with LVD as well as the following single-ended SCSI
types: SCSI-1, Fast SCSI, Wide Fast SCSI, Ultra
SCSI, Wide Ultra SCSI, and Wide Ultra2 SCSI.

13. Safety check the installation by checking Pin 1 locations and cable

types. For more details, see step 3 in the section titled “Before You
Begin (Standard)” on page 2-2.

14. Replace the cover and connect the power cord.

The standard AcceleRAID 150 installation is complete.

Proceed to the next chapter for controller start-up procedures and other setup
options.