Initial Installation

QUALIFIED INSTALLERS ONLY

Vertical

Termination

Storm Collar

Flashing

Roofing nails

Elbow Strap

the exposed sections, bend

the support straps outwards,

and push the elbow strap

down to the roof level, as

shown in Figure 15. Tighten

the clamp around the pipe

section. Use a level to make

sure the pipe is truly vertical.

With roofing nails, secure the

support straps to the roof.

Seal the nails holes heads

with non-hardening mastic.

Trim the excess length of the

support straps that extend

out beyond the edge of the

flashing.

STEP 7. Slip the flashing over the pipe

section protruding through

the roof. Secure the base

of the flashing to the roof

with roofing nails. Use a
non-hardening sealant between the uphill edge

of the flashing and the roof. Insure the roofing

material overlaps the top edge of the flashing as

shown in Figure 15. Verify that you have at least

the minimum clearance to combustibles at the

roof line.

STEP 5. Cut hole in the roof centered on the small hole placed in the roof from Step 2. The hole should be of

sufficient size to meet minimum requirements for Clearance to Combustibles, as specified. Continue to

assemble lengths of pipe and elbows necessary to reach from the ceiling support box up through the roof

line. Galvanized pipe and elbows may be utilized in the attic, as well as above the roof line. The galvanized

finish is desirable above the roof line, due to the higher corrosion resistance.

STEP 6. Once the pipe sections have been joined, and run up through the hole in the roof, slip an elbow strap over

Figure 15: Vertical Vent Termination Installation.

Table 3: Minimum ‘H’ for Figure 16

Roof Pitch

Minimum Height

Feet

Meters

Flat to 7/8

1

0.3

Over 7/12 to 8/12

1.5

0.46

Over 8/12 to 9/12

2

0.61

Over 9/12 to 10/12

2.5

0.76

Over 10/12 to 11/12

3.25

0.99

Over 11/12 to 12/12

4

1.22

Over 12/12 to 14/12

5

1.52

Over 14/12 to 16/12

6

1.83

Over 16/12 to 18/12

7

2.13

Over 18/12 to 20/12

7.5

2.29

Over 20/12 to 21/12

8

2.44

Figure 16: Height of Vertical Termination;

Reference Table 3.