Venting into a class ‘a’ chimney, Mobile home installation, Initial installation – Enviro EG28 DV User Manual

Page 18

Advertising
background image

18

Initial Installation

QUALIFIED INSTALLERS ONLY

V

ENTING

INTO

A

C

LASS

‘A’ C

HIMNEY

:

This model is also certified and tested to vent into CLASS ‘A’ wood

stove chimneys.
Place the freestanding direct vent appliance in the desired location.
Use a conversion kit from Simpson Duravent (931, 932, or 933), or

Security Chimney (SV4CCK1, SV4CCK2, or SV4CCK1). Which kit is used

will depending on the inner diameter of the CLASS ‘A’ chimney that this

appliance is to be vented into.
Place a bead of high temperature silicone or Mil-Pac at each connection

to ensure a tight seal.
NOTE: An approved 4” (10 cm) diameter flex liner must be used in the

application.
NOTE: Use Simpson Dura Vent from the top of the appliance until this

vent reaches the CLASS ‘A’ chimney. Install the retro adapter to the

top section of GS direct vent pipe and install the flex liner to the retro

adapter.
Fully line the CLASS ‘A’ chimney with a minimum 4” (10 cm) flex liner

to the top of the CLASS ‘A’ chimney.
Place a bead of high temperature silicone to the Simpson Cap adapter

and securely attach the flex liner to the adapter.
Secure the cap adapter to the CLASS ‘A’ chimney ensuring an airtight

seal.
Install the vertical termination cap.
Light the unit and ensure proper operation.
THE USE OF ANY EXISTING CHIMNEY AS AN AIR INTAKE IS NOT

COVERED UNDER THE ANSI Z21.88-2002 CSA 2.33a-2002 TEST

METHODS AND THE RESULTING ITS/WH PRODUCT CERTIFICATION.

THE CODE AUTHORITY HAVING JURISDICTION MUST BE CONSULTED

PRIOR TO PROCEEDING WITH THIS INSTALLATION METHOD.

Figure 24: Assembly of Venting into a

Class ‘A’ Chimney.

M

OBILE

H

OME

I

NSTALLATION

:

• When the unit is installed in a Mobile Home it must

be grounded to the steel chassis or connected to a

grounding rod.
• In a Mobile Home installation the unit must be bolted

securely to the floor using the holes provided.
• Manufactured (mobile) home installation must be in

accordance with the Manufactured Home Construction

and Safety Standard, UL 307B, Title 24 CFR, Part

3280 and/or The Standard for Manufactured Home

Installations, ANSI A225.1/NFPA 501A

Holes for screws to

hold down the unit.

Figure 25: Screw the pedestal down for mobile homes.

Advertising
This manual is related to the following products: