V

ENT

P

ARTS

:

This fireplace have been tested and certified for use with SIMPSON DURAVENT TYPE GS PIPE FOR GAS STOVES.

SELKIRK DIRECT-TEMP SYSTEM SECURITY CHIMNEY’S “SECURE VENT DIRECT VENT SYSTEM” and SELKIRK

“DIRECT TEMP VENT SYSTEM” kits are available for horizontal venting. When using Simpson Duravent, it is

recommended that, before installation, a bead of RTV High Temperature Silicone should be applied to each outer

vent joint, and Mil-Pac to each inner joint. When planning an installation, it will be necessary to select the proper

length of vent pipe for the particular requirements.

A MINIMUM VERTICAL LENGTH OF 24” (61 cm) TO THE FIRST 90° ELBOW IS REQUIRED. WITH THIS

MINIMUM VERTICAL RISE, HORIZONTAL RUNS OF FROM 1 FOOT (30.5 cm) to 3 FEET (91.5 cm) ARE PERMITTED

TO REACH THE OUTSIDE VENT TERMINATION.

BEFORE BEGINNING THE INSTALLATION TAKE CARE TO ENSURE AN APPROPRIATE OUTSIDE LOCATION FOR THE

VENT TERMINATION CAN BE ACCOMMODATED. FOLLOW THE VENT LENGTH DIAGRAM PRECISELY.

VENTING TERMINALS CANNOT BE RECESSED INTO A WALL OR SIDING.

Simpson Duravent (SD), Selkirk (SEL), and Security Chimneys (SC), must state if galvanized or black wanted, PART NUMBERS:

SD

SEL

SC

Description

SD

SEL

SC

Description

908

4DT-6

SV4L6

6” pipe length

911

11” to 14

5

/

8

” pipe, adjustable

907

4DT-9

9” pipe length

4DT-AJ

4” to 10” pipe , adjustable

906

4DT-12

SV4L12

12” pipe length

SV4LA12

11⁄2” to 12” pipe , adjustable

904

4DT-24

SV4L24

24” pipe length

943

4DT-AF6

Flashing, 0/12 to 6/12 roof pitch

903

4DT-36

SV4L36

36” pipe length

943S 4DT-AF12

Flashing, 7/12 to 12/12 roof pitch

902

4DT-48

SV4L48

48” pipe length

SV4FA

Flashing, 1/12 to 7/12 roof pitch

945

4DT-EL45 SV4EBR45 45° elbow, black

SV4FB

Flashing, 8/12 to 12/12 roof pitch

990

4DT-EL90 SV4EBR90 90° elbow, black

943F

SV4F

Flat flashing

950

4DT-VS

SV4VS

Vinyl siding standoff/sheild

980

4DT-VC

SV4CGV

Vertical termination

942

4DT-WT

SV4RSN

Wall thimble

991

4DT-HVC

High wind vertical termination

941

4DT-CSS

SV4CSB

Cathedral Support Box

984

4DT-HC

SV4CHC

Horizontal square termination

981

4DT-ST36 SV4STC36 36” Snorkel Termination

985

4DT-HHC

High wind horizontal termination

953

4DT-SC

SV4FC

Storm collar

978

4DT-VKC

SV0FAK

Vertical termination kit

963

4DT-FS

SV4BF

Fire stop

970

4DT-HKA

SV0SHK

Horizontal termination kit

SD: Basic Kit, SEL: Kit A, SC: Standard Kit

988

4DT-WS/B

SV4BM

Wall strap/support/band

971

4DT-HKB

SV0SHK2 Horizontal termination kit

SD: Kit A, SEL: Kit B, SC: Kit

Initial Installation

QUALIFIED INSTALLERS ONLY

Table 2: Vent Pipe Types with Part Numbers.

For horizontal venting installations Sherwood Industries Ltd.’s DV Kit with Coupler (part# EC-061) can be used, refer

to “Initial Installation - Freestanding Direct Vent Kit with Coupler.”

Advertising
This manual is related to the following products: