Yaskawa Σ-V Series AC Servo Drives Rotational Motor MECHATROLINK-II User Manual
Page 232
Advertising

6.15 Vibration Detection Level Initialization (Fn01B)
6-33
6
Utili
ty Fu
ncti
ons (Fn
)
(2) Operating Procedure
Use the following procedure.
1.
In the SigmaWin+ main window, click
Setup
-
Initialize Vibration Detection Level
.
The
Initialize Vibration Detection Level
box will appear.
2.
Select a percentage for
Pn311: Vibration Detection Sensibility
and one condition in
Pn310:
Vibration Detection Switch
, and then click
Detection Start
.
The name of the button will change from
Detection Start
to
Execute
to indicate that detection is ready to
be executed.
MECHA