Yaskawa Σ-V Series AC Servo Drives Rotational Motor MECHATROLINK-II User Manual

Page 304

Advertising
background image

9.1 List of Parameters

9-25

9

Ap

pend

ix

Pn827

2

Linear Deceleration Con-
stant 1 for Stopping

1 to 65535

10000

refer-

ence

unit/s

2

100

Immedi-

ately

*3

Setup

*1

Pn829

2

SVOFF Waiting Time

(SVOFF at deceleration to
stop)

0 to 65535

10 ms

0

Immedi-

ately

*3

Setup

*1

Pn82A

2

Option Field Allocation 1

0000 to 1E1E

1813

After restart

Setup

*1

Pn82B

2

Option Field Allocation 2

0000 to 1F1F

1D1C

After restart

Setup

*1

∗1.

For details, refer to

Σ

-V Series User’s Manual MECHATROLINK-II Commands

(Manual No.: SIEP S800000 54).

∗3.

Change the setting when the reference is stopped (DEN is set to 1), because the change will affect the output during
operation.

(cont’d)

Parameter

No.

Size

Name

Setting

Range

Units

Factory

Setting

When

Enabled

Classification

Reference

Section

4th

digit

3rd

digit

2nd

digit

1st

digit

n.

0 to E

ACCFIL bit position

0

1

Disables ACCFIL bit allocation.

Enables ACCFIL bit allocation.

0 to E

GSEL bit position

0

1

Disables GSEL bit allocation.

Enables GSEL bit allocation.

4th

digit

3rd

digit

2nd

digit

1st

digit

n.

0 to F

V_PPI bit position

0

1

Disables V_PPI bit allocation.

Enables V_PPI bit allocation.

0 to F

P_PI_CLR bit position

0

1

Disables P_PI_CLR bit allocation.

Enables P_PI_CLR bit allocation.

Advertising