6

Installation

!

WaRnIng

  •  Personal injury, equipment damage, or 

leakage due to escaping gas or

bursting of pressure-containing

parts might result if this regulator

is overpressured or is installed where

service conditions could exceed

the limits for which the regulator was

designed, or where conditions exceed

     any ratings of the adjacent piping or 

piping connections. To avoid such

     injury or damage, provide pressure-

relieving or pressure-limiting devices

(as required by the appropriate code,

regulation, or standard) to prevent

service conditions from exceeding

those limits.
  •  A regulator may vent some gas to the 

     atmosphere in hazardous or flammable 

gas service, vented gas might

     accumulate and cause personal injury, 

     death or property damage due to fire or 

explosion. vent a regulator in

hazardous gas service to a remote,

safe location away from air intakes or

any hazardous location. The vent

line or stack opening must be

protected against condensation

or clogging.

Like most regulators, the Type 99 regulator has a outlet

pressure rating lower than its inlet pressure rating.
Complete downstream overpressure protection is

needed if the actual inlet pressure can exceed the

regulator outlet pressure rating or the pressure ratings

of any downstream equipment. Although the Type H110

relief valve provides sufficient relief capacity to protect

the extra high pressure pilot of the 1000 psig (69,0 bar)

maximum inlet regulator in case the Type 1301F supply

regulator fails open, this protection is insufficient if the

main valve body fails open. Regulator operation within

ratings does not preclude the possibility of damage from

external sources or from debris in the lines. A regulator

should be inspected for damage periodically and after

any overpressure condition.

!

WaRnIng

The 1000 psig (69,0 bar) maximum

inlet regulator must not be used on

hazardous gas service unless the

Type H110 relief valve can be vented

into a safe area. If vented gas can

accumulate and become a hazard in

enclosed conditions such as in a pit,

underground, or indoors, the relief valve

must be repiped to carry the gas to a

safe location.
a repiped vent line or stack must be

located to avoid venting gas near

buildings, air intakes, or any hazardous

Table 3. Maximum Allowable Drop and Minimum Differential Pressures

MaXIMUM

aLLOWaBLE

PRESSURE

DROP, PSIg (bar)

MaIn vaLvE SPRIng

MInIMUM

DIFFEREnTIaL

PRESSURE FOR FULL

STROKE, PSIg (bar)

SEaT MaTERIaL

MaXIMUM PORT

DIaMETER

(1)

,

InCHES (mm)

Part

number

Wire Diameter,

Inches (cm)

Free Length,

Inches (cm)

25 (1,72)

1C277127022

0.148 (0,38)

6 (15,2)

0.75 (0,05)

Nitrile (NBR), Neoprene (CR),

Fluorocarbon (FKM)

1-1/8 (28,6)

50 (3,45)

1N801927022

0.156 (0,40)

7-1/8 (18,1)

1.5 (0,10)

Nitrile (NBR), Neoprene (CR),

Fluorocarbon (FKM)

1-1/8 (28,6)

150 (10,3)

1B883327022

0.187 (0,47)

6-5/8 (16,8)

3 (0,21)

Nitrile (NBR), Neoprene (CR),

Fluorocarbon (FKM)

1-1/8 (28,6)

175 (12,1)

1B883327022

0.187 (0,47)

6-5/8 (16,8)

3 (0,21)

Nitrile (NBR)

(2)

, Neoprene (CR)

(2)

,

Fluorocarbon (FKM)

(2)

7/8 (22,2)

250 (17,2)

1B883327022

0.187 (0,47)

6-5/8 (16,8)

3 (0,21)

Nitrile (NBR), Fluorocarbon (FKM)

7/8 (22,2)

0W019127022

0.281 (0,71)

6 (15,2)

10 (0,69)

Nitrile (NBR)

(3)

, Fluorocarbon (FKM)

(3)

1-1/8 (28,6)

300 (20,7)

0W019127022

0.281 (0,71)

6 (15,2)

10 (0,69)

Nylon (PA)

1-1/8 (28,6)

400 (27,6)

0W019127022

0.281 (0,71)

6 (15,2)

10 (0,69)

Nylon (PA)

7/8 (22,2)

600 (41,4)

0W019127022

0.281 (0,71)

6 (15,2)

10 (0,69)

Nylon (PA)

5/8 (15,9)

1000 (69,0)

0W019127022

0.281 (0,71)

6 (15,2)

10 (0,69)

Nylon (PA)

1/2 (12,7)

(4)

1. Can use all port diameters up to maximum size listed.

2. CL125 FF flanged body only.

3. O-ring seat only.

4. 1/2-inch (12,7 mm) is the only orifice available for 1000 psig (69,0 bar) maximum inlet pressure regulator.

Advertising