2 power down/up timing, Figure 710: power down/up timing, Table 710: power down/up timing – Epson S1D13705 User Manual

Page 43: Power down/up timing, Table 7-10: power down/up timing, Figure 7-10: power down/up timing

Advertising
background image

Epson Research and Development

Page 37

Vancouver Design Center

Hardware Functional Specification

S1D13705

Issue Date: 02/02/01

X27A-A-001-10

7.3.2 Power Down/Up Timing

Figure 7-10: Power Down/Up Timing

Table 7-10: Power Down/Up Timing

Symbol

Parameter

Min

Typ

Max

Units

t1

HW Power Save active to FPLINE, FPFRAME, FPSHIFT, FPDAT, DRDY
inactive - LCDPWR Override = 1

1

Frame

t2

HW Power Save inactive to FPLINE, FPFRAME, FPSHIFT, FPDAT, DRDY
active - LCDPWR Override = 1

1

Frame

t3

HW Power Save active to FPLINE, FPFRAME, FPSHIFT, FPDAT, DRDY
inactive - LCDPWR Override = 0

1

Frame

t4

LCDPWR low to FPLINE, FPFRAME, FPSHIFT, FPDAT, DRDY inactive
- LCDPWR Override = 0

127

Frame

t5

HW Power Save inactive to FPLINE, FPFRAME, FPSHIFT, FPDAT, DRDY,
LCDPWR active - LCDPWR Override = 0

0

Frame

t6

LCDPWR Override active (1) to LCDPWR inactive

1

Frame

t7

LCDPWR Override inactive (1) to LCDPWR active

1

Frame

t4

t3

t1

Active

Inactive

Active

Inactive

Active

LCDPWR Override

(REG[03h] bit 3)

HW Power Save

FP Signals

LCDPWR

t2

Software Power Save

11

00

11

00

11

t5

t6

t7

REG[03h] bits [1:0]

or