2.5 ALARM IN- / OUT INSTALLATION


Alarm- in- and outputs are connected to the screwless terminal at backside of the camera.

For Details to input/output circuit refer to Attachment A.

2.5.1 Terminal pin assignment:

Contact Description

1

Alarm IN 1 + (max 50 V DC)

2

Alarm IN 1 -

3

Alarm IN 2 + (max 50 V DC)

4

Alarm IN 2 -

5

Relay COM (max. 24 V DC / 1 A)

6

Relay N.C. (max. 24 V DC / 1 A)

7

Relay N.O. (max. 24 V DC / 1 A)

8 RS-485+
9 RS-485-

10

+ 3,3 VDC Output

11 GND

Both alarm inputs are opto-coupler inputs and require DC Voltage 3~50 VDC for activation.

2.5.2 Alarm Inputs

Following connection methods are possible:

A) Installation of dry N.O. contact with camera power source

Alarm In 1

Alarm In 2

Advertising