Transport controls – Moog Subharmonicon Semi-Modular Polyrhythmic Analog Synthesizer User Manual
Page 28

29
TRIGGER
(Continued)
If the
EG
button is Off (unlit), the
TRIGGER
button behaves as a gate, and the envelopes are held to
their maximum levels (based on their current settings) as long as the
TRIGGER
button is held down.
When the
TRIGGER
button is released, the Decay phase of the EGs will begin, allowing an extra degree
of control over the EG. If the
EG
button is in the Held position (blinking), then the EGs are already being
held to their maximum levels, and the
TRIGGER
button will have no effect.
NOTE:
This button is also linked to the output of the rhythm generators and the trigger inputs. The combined
signal is sent to the
TRIGGER
output jack.
RESET
Pressing the
RESET
button will instantly reset the sequencers to Step 1, and
will reset the rhythm generators to their initial phase or starting point. If the
PLAY
button is lit when the
RESET
button is pressed, the sequencers
will begin again on the next clock pulse. If the
PLAY
button was unlit when
the
RESET
button was pressed, the sequencers will not restart until the
PLAY
button is pressed again.
Holding the
RESET
button down will act as a Hold function. The sequencers
will reset to Step 1, but will not advance to the next step. However, the EGs will continue to be triggered
by the rhythm generators assigned to that sequencer. Pressing the
NEXT
button while the
RESET
button is being held down will advance the sequencer(s) to the next step, where the EGs will continue
to be triggered by the rhythm generators assigned to the sequencer(s). Normal playback will resume
when the
RESET
button has been released.
NOTE:
This button is combined with the
RESET
input jack.
TIP:
Using the
RESET
button is a handy way to bring everything (sequencers, rhythm generators, EGs, etc.) back
to a single starting point during performance in order to begin a second verse, move to the chorus, start a new
section, or even create a stuttered one-count, etc.
NEXT
Pressing the
NEXT
button will immediately advance to the next step of the
sequencer(s).
NOTE:
Pressing the
NEXT
button will not cause the VCF EG or the VCA EG to re-trigger,
except as defined when holding down the
RESET
button (above), or if a gate signal is
being received at the
RESET
input jack.
EG
The
EG
(Envelope Generator) button has three settings; Off (button is unlit), On
(button is lit), and Held (button blinks). Quickly press the
EG
button to toggle
between the On and Off settings. Hold the
EG
button until it begins to blink to
select the Held setting.
OFF:
This setting prevents the individual sequencer steps from triggering the
EGs. The
TRIGGER
button and external trigger pulses continue to trigger the
EGs, and are passed to the
TRIGGER
output jack.
ON:
This setting allows the individual sequencer steps to trigger the EGs. All of the manual triggers,
external triggers, and triggers created by the sequencers are passed to the
TRIGGER
output jack.
TRANSPORT CONTROLS
(Continued)