Connect the battery, Specifications – APC Back-UPS BN450M User Manual
Page 2
Back-UPS BE425M/425M-LM, BN450M/450M-CA
2
Connect the Battery
The Back-UPS is shipped with one battery cable disconnected.
Specifications
Remove the
“Stop! Connect the Battery”
label
that covers the outlets.
The battery connector is located on the
underside of the unit.
Slide the battery connector handle away from its
disconnected position.
Turn the battery connector to a 90-degree
upright position and push it into the unit.
Model
BE425M / BE425M-LM
BN450M / BN450M-CA
Input
Voltage
120 Vac
Nominal
Frequency
50/60 Hz + 1Hz auto-sensing
Brownout Transfers
92 Vac Typical
Over-voltage Transfer
139 Vac Typical
Output
UPS Capacity
425 VA, 255 W
450 VA, 255 W
No. of Outlets
6
Battery Backup/Surge Outlets
4 / 2
Total output current
6A
Voltage - On Battery
115 Vac ± 8%
Frequency - On Battery
50/60 Hz + 1 Hz
Transfer Time
4 ms Typical
Protection
and
Filtering
EMI/RFI Filter
Full time
AC Input
Resettable circuit breaker
Battery
Type
Sealed, maintenance-free, lead acid, 12V
Average Life
3 - 5 years, the number of discharge cycles, poor
quality AC power, environmental temperature and
humidity may shorten the battery lifetime
Charging Time
8 hours
bu46
2a
bu46
3a
bu46
4a
bu46
5a