Back-UPS BE425M/425M-LM, BN450M/450M-CA

5

Status Indicators

LED

Flashes

Sensitivity

Setting

Input Voltage

Range

(AC Operation)

Recommended Use

Green

LOW

88 Vac to 142 Vac

Use this setting with equipment that is

less sensitive to fluctuations in voltage

or waveform distortions.

Red

MEDIUM 92 Vac to 139 Vac

Factory default setting. Use this setting

under normal conditions.

Amber

HIGH

96 Vac to 136 Vac

Use this setting when connected

equipment is sensitive to voltage and

waveform fluctuations.

Status

Power Button

illumination

Audible

Indicator On

Audible Indicator

Terminates

Power On

The Back-UPS is supplying AC power to

connected equipment.

Solid green

None

N/A

On Battery

Back-UPS supplying battery power to

battery backup outlets.

Solid green

and flashes

twice every 2

seconds.

The audible

alarm

depends on

the On

Battery

Indicator

mode

setting. See

the

On

Battery

Indicator

Modes

section for

full details.

- Using Quick Mute

- Beeping stops when AC

power is restored or the

Back-UPS is turned off.

Applies only to modes

where the on battery

alarm is audible.

Low Battery notification

The Back-UPS is supplying battery

power to the battery backup outlets and

the battery is near a total discharge state.

Flashes green

in rapid

succession.

Low Battery shutdown

The battery has been completely

discharged while the Back-UPS is on

battery, the UPS will shut down.

None

- AC power is restored

- AC is not restored within

32 seconds

- The Back-UPS is turned

off.

Sleep Mode

The UPS has shut down and will

“awaken” once AC power is restored

None

None

N/A

Replace Battery

• The battery is disconnected.

• The battery needs to be charged, or

replaced.

• Alternates

green-red

• Constant

tone

- Back-UPS is turned off

- If battery is disconnected,

unplug the Back-UPS

from AC source and then

turn it off. Refer to the

section

“Connect the

Battery” on page 2

.

- If battery needs

replacement, refer to the

section

“Battery

Replacement” on page 8

for details.

Detected Overload

An overload condition has occurred in

one or more of the battery backup outlets

while operating on battery power.

None

Constant

tone

Back-UPS is turned off