Turn off the back-ups, Quick mute, On battery indicator modes – APC Back-UPS BN450M User Manual

Page 4: Voltage sensitivity adjustment (optional)

Advertising
background image

Back-UPS BE425M/425M-LM, BN450M/450M-CA

4

Turn Off the Back-UPS

Press the POWER button for at least 2 seconds. At the first beep, release the button and

the UPS will turn off. A 2 second delay has been added to mitigate unintentional contact

with the POWER button.

Quick Mute

The Back-UPS is able to temporarily mute user correctable alarms such as On Battery.
During such alarms, a short press (less than 2 seconds) of the POWER button will

temporarily mute the alarm until the condition has been reset. A short double beep will

confirm that Quick Mute has been activated. Pressing the POWER button for more than

2 seconds will turn off the UPS.
Other critical events such as Battery replacement and Charger notification can not be

temporarily muted. The unit in these cases must be turned off.

On Battery Indicator Modes

With the UPS turned on, configuring the On Battery Indicator modes below is done by

holding down the POWER button and waiting for the third beep. At the third beep, the

POWER button will cycle red / green. Release the POWER button and its color will

indicate the mode the UPS is in. Press the POWER button to cycle through each mode.

See the following table for the 3 mode selection colors. Once the mode has been

selected, wait 5 seconds and the setting will be committed to the UPS.

Voltage Sensitivity Adjustment (optional)

The Back-UPS detects and reacts to line voltage distortions by transferring to battery

backup power to protect connected equipment. In situations where either the Back-UPS

or the connected equipment is too sensitive for the input voltage level it is necessary to

adjust the transfer voltage.

1. Turn off the UPS while connected to a wall outlet.
2. Press and hold the

ON/OFF

button for 10 seconds. The POWER button will alternate green-

red to indicate that the Back-UPS is in

Program

mode.

3. The POWER button will flash either green, amber, or red to indicate the current sensitivity

level. Refer to the table for an explanation of the transfer voltage sensitivity levels.

4. To exit

Program

mode wait five seconds and all LED indicators will extinguish.

Program

mode is no longer active.

Mode

Visual

Indicator

Audible Indicator

Mode Selection

Color

Quiet Alarm

(default)

The POWER

button is solid

green and

flashes twice

every 2 seconds

until Low

Battery

notification

where it will

flash green in

rapid

succession.

No alarm until Low Battery

notification where the alarm beeps

twice every 30 seconds

Flashing green

No Alarm

No alarm while the UPS is On

Battery

Flashing red

Full Alarm

Alarm sounds 4 beeps every 30

seconds until Low Battery

notification where the alarm beeps

every half second. As the UPS shuts

down, it sounds one beep every 4

seconds

Flashing amber