Leveling the range, Engaging the anti-tip device – LG 30 Inch Double Oven Gas Range Owners Manual User Manual

Page 20

Advertising
background image

20

INSTALLATION

Checking Operation of Bake / Broil

Burners

To check ignition of the Bake burner, follow the steps

below:

1

Remove all packing from inside the oven cavity.

2

Touch

Bake

. 350 °F appears in the display.

3

Touch

Start

.

It may take between 30 and 90 seconds for the

burner to start heating.
To check ignition of the Broil burner, follow the steps

below:

1

Touch

Broil. Hi

appears in the display.

2

Make sure the door is closed.

3

Touch

Start

.

It may take between 30 and 90 seconds for the

burner to start heating.

NOTE

Do not try to light either the Bake or Broil burners

during a power outage. The range has an

electrical ignition system and cannot be used

without power.

Adjusting Air Shutters (for LP

Conversions)

The range comes from the factory with the air

shutters adjusted for proper air flow for natural gas.

If converted to LP, follow the instructions provided in

the conversion kit to properly adjust the air shutters.

LP conversion must be performed by a qualified

technician.

Leveling the Range

Level the range by adjusting the leveling legs.

Extending the legs slightly may also make it easier to

insert the rear leg into the anti-tip bracket.

Use a level to check your adjustments. Place the level

diagonally on the oven rack, and check each direction

for level.
First check direction .
Then check direction . If the level doesn’t show level

on the rack, adjust the leveling legs.

1

2

Engaging the Anti-tip Device

Anti-tip

bracket

Leveling leg

1

Slide the range against the wall, making sure

the back leg slides into and engages the anti-tip

bracket.

2

Check for proper installation by grasping

the front edge of the cooktop and carefully

attempting to tilt the range forward.