English – haier CHDE5300AW User Manual

Page 9

Advertising
background image

1. Only rigid metal duct work should be used.
2. Venting vertically through a roof may expose the exhaust system to down

drafts causing an increase in vent restriction.

3. Running the exhaust system through an uninsulated area may cause

condensation and faster accumulation of lint.

4. Compression of crimping of the exhaust system will cause an increase in

vent restriction.

5. In Canada, that only those foil-type flexible ducts, if any, specifically identified

for use with the appliance by the manufacturer shall be used. In the United

States, that only those foil-type flexible ducts, if any, specifically identified

for use with the appliance by the manufacturer and that comply with the UL

Outline for clothes Dryer Transition Duct, Subject 2158A (2006), shall be

used.

6. In Canada, that the exhaust duct shall be 102 mm in diameter. In the United

States, the required exhaust duct diameter.

The exhaust system should be inspected and cleaned a minimum of every 12

months with normal usage. The more the dryer is used the more often you should

check the exhaust system and vent hood for proper operation.

Side and Bottom Exhaust

For your convenience, your dryer can be exhausted through the side or the

bottom. If you need to change the exhaust on the dryer to the side or the

bottom of the cabinet, you will need to order the exhaust kit from your Haier

dealer or call 1- 800-313-8495

English

8

RECOMMENDED MAXIMUM

Exhaust Hood Types

Recommended

Use only for short

run installations

No. of 90º

elbows

Rigid Metal

Rigid Metal

0

90 ft.

60 ft.

1

60 ft.

45 ft.

2

45 ft.

35 ft.

3

35 ft.

25 ft.

The total length of flexible metal duct shall not exceed

94 inches.