Configuration, Ns-series server, Table 4-1 – HP FIBRE CHANNEL TO SCSI ROUTER M8201R User Manual

Page 35

Advertising
background image

M8201R Fibre Channel to SCSI Router Installation and User’s Guide 529971-005

4 -1

4

Configuring the Fibre Channel to
SCSI Router for the NonStop
NS-Series Server

This section includes:

Configuration

1. In SCF, issue this command:

SCF> ADD TAPE $tape, SENDTO STORAGE, LOCATION (group, module,
slot), SAC sac-id, PORTNAME 64-bit-portname, LUN lun-id

Example:

SCF> ADD TAPE $TAPE1, SENDTO STORAGE, LOCATION (110,2,3), SAC
1, PORTNAME 100000E00C00F000, LUN 1

The Fibre Channel to SCSI router can also be connected to a tape library.

Table 4-1

shows the SCSI ID, router port number, and the LUN address for a tape

library and a tape drive.

Configuration

4-1

Note. The LUN (logical unit number) in SCF should be 1 for the tape drive that is on bus 0 and
3 for the tape drive that is on bus 1.

Note. PORTNAME in SCF corresponds to the WWP name of the router. This name is located
on the back of the device.

Table 4-1. LUN Mapping Table for the Fibre Channel to SCSI Router

DEVICE

SCSI ID

Router PORT

LUN ADDRESS

Tape library

3

0

LUN 0

Tape drive

5

0

LUN 1

Tape library

3

1

LUN 2

Tape drive

5

1

LUN 3

Advertising