HP 16500C User Manual

Page 22

Advertising
background image

To verify that all stacks and registers are restored
correctly before exiting a subroutine

The exit code for a function will often contain instructions for deallocating
stack storage for local variables and restoring registers that were saved
during the function call. Some language implementations vary on these
points, with the calling function doing some of this work, so you may need to
adapt the procedure to suit your system.

1

Select the state analyzer Trigger menu.

2

Define terms SR_START and SR_END to represent the start and end
addresses of the subroutine.

3

Under State Sequence Levels, enter the following sequence
specification:

While storing “anystate” Find “SR_START” 1 time

While storing “anystate” Then find “SR_END” 1 time

While storing “anystate” TRIGGER on “

SR_START” 1 time Else on

“SR_START” go to level 2

Store “anystate”

Verifying Correct Return from a Function Call

Triggering
To verify that all stacks and registers are restored correctly before exiting a
subroutine

1–12

Advertising
This manual is related to the following products: