HP Anab EQ5 User Manual

Page 30

Advertising
background image


EQ5 AC Drive Operations Manual

______________________________________________________________________

TECO – Westinghouse Motor Company DC Link Chokes 24

2-3-6 DC Link Choke Wattage Loss

Fig. 2-3-12 DC Link Choke

Note: Please refer to Sec. 8- 3- 4 for dimensions and weights.

Input

Voltage

Hp

Model No.

Loss

(Watts)

230V

100/75

DCR2-75B

55

125/100

DCR2-90B

57

150/125

DCR2-110B

67

460V

100/75

DCR4-75B

58

125/100

DCR4-90B

64

150/125

DCR4-110B

73

200/150

DCR4-132B

84

250/200

DCR4-160B

90

300/250

DCR4-200B

126

350/300

DCR4-220B

131

400/350

DCR4-280B

133

450/350

DCR4-280B

150

500/400

DCR4-355B

205

600/450

DCR4-400B

215

700/500

DCR4-450B

272

800/600

DCR4-500B

292

Notes:
• EQ5 Drives rated 100 Hp and above are furnished with a DC link choke. This choke
must be installed between terminals P1 and P+ prior to applying power to the Drive.
• The weight of the DC Link Reactor is not included as part of weight referenced for the Drive.
• The DC Link choke is provided as open type and is separately mounted. Any enclosures are
to be provided by the user.

Advertising