Montana installation instructions – Hearth and Home Technologies Montana-36 User Manual

Page 16

Advertising
background image

16

4039-150 Rev B

01/04

MONTANA INSTALLATION INSTRUCTIONS

11. Install the Chimney Air Kit

When installing the chimney air kit, follow the instructions

provided with this accessory.

Figure 17- Cooling Air Location

Note:

The cooling air kit must terminate at least six

feet above ground level.

10. Install the Cooling Air Kit (furnished)

The cooling air kit is supplied as a standard feature

with this fireplace and is required for safe operation.

Installation must be done at the time of initial

construction. The cooling air inlet tubes must be a

minimum of 72” above the base of the fireplace. This

is to prevent potential blockage by snow or yard debris.

See Figure 17.

To install the air kit collar, slide one of the tabs down

into the seam. See Figure 18. Secure the collar tabs

to the fireplace with screws placed into the holes

provided. See Figure 19.

Repeat for the other side.

Figure 18 - Slide the Tabs

Figure 19 - Secure the Tabs