Montana installation instructions – Hearth and Home Technologies Montana-36 User Manual

Page 14

Advertising
background image

14

4039-150 Rev B

01/04

MONTANA INSTALLATION INSTRUCTIONS

WARNING!

Maintain a minimum of 2” air clearance to all parts of

the chimney system at all times! Failure to maintain

this 2” air clearance will cause a structure fire.

CAUTION:

Inner flue and outer liner sections cannot be disas-

sembled once locked together. Plan ahead to ensure

the proper installation height is achieved with the se-

lected chimney components.

Figure 12 - Installing an Insulation Shield

Note:

You must provide support for the pipe during con-

struction and check to be sure inadvertent loading has not

dislodged the chimney section from the fireplace or at any

chimney joint.

WARNING!

When chimney sections exceeding six feet in

length are installed between an offset and re-

turn, structural support must be provided to re-

duce off-center loading and prevent chimney

sections from separating at the chimney joints.

Figure 13 - Offset/Return with Stabilizer

7. Double-check the Chimney Assembly

Continue assembling the chimney sections up through the

firestop spacers as needed. While doing so, be aware of the

height and unsupported chimney length limitations that are

given on page 10 under “Chimney Requirements”.

Check each section by pulling up slightly from the top to ensure

proper engagement before installing the succeeding sections.

If they have been connected correctly, they will not disengage

when tested.

8. Secure the Chimney System

When offsets and returns are joined to straight pipe sections,

they must be locked into position with the screws provided

(outer only), using the predrilled holes. To prevent gravity from

pulling the chimney sections apart, the returns and the

chimney stabilizers have straps for securing these parts to

joists or rafters. See Figure 13.

6. Attic Insulation Shield

An insulation shield should be installed when there is a

possibility of insulation coming into contact with the factory

built chimney system.
a. Bend the tabs at the top of the attic insulation shield

inward. This will help keep the chimney section centered

in the shield.

b. Position the shield over the vertical chimney section

where it penetrates a firestop spacer.

c. Slide the shield down until it rests on the firestop spacer.

The firestop spacer will support the insulation shield. See

Figure 12.

WARNING! RISK OF FIRE.

Do not fill the space between the chimney sec-

tion and the insulation shield with insulation.