Montana installation instructions – Hearth and Home Technologies Montana-36 User Manual

Page 18

Advertising
background image

18

4039-150 Rev B

01/04

MONTANA INSTALLATION INSTRUCTIONS

Figure 21 - Factory Built Hearth Extension

Figure 22 - Field Constructed Hearth Extension

WARNING!

Hearth extensions are to be installed only as illustrated to prevent high temperatures from occurring

on concealed combustible materials. Hearth sealing strips prevent burning or hot particles from

inadvertently falling directly on combustible surfaces in the event the building should settle and

disturb the original construction.

14. Hearth Extension

A hearth extension must be installed with all fireplaces to protect the combustible floor in front of the fireplace from both radiant heat

and sparks.

The construction of, and materials used for a hearth extension are shown in Figures 21 and 22. A hearth extension of this construction

may be covered with any noncombustible decorative material and may have a maximum thickness as per the illustration. Seal

gaps between the hearth extension and the front of the fireplace with a bead of noncombustible sealant.

Field constructed hearth extensions should be constructed in accordance with the instructions in Figure 22. The field constructed

hearth extension must be constructed from ½” MICORE CV230, or a material with an equivalent insulation value.