Isle Royale Wood Stove

250-5763C

SOLID PACK CHIMNEY WITH METAL SUPPORTS AS A THIMBLE

Figure 12A

Center of Hole

Wall

Center Line

Opening

Center Line

CL

26-7/16"

(570mm)

Add the 26-7/16 inches (671mm), center-line

measurement to the depth measurement of

your floor protector. Mark this combined mea-

surement at the correct wall location for your

installation, maintaining minimum clearance to

combustibles.

FLOOR PROTECTOR

THIMBLE,

12" (305mm)

OF BRICK

AIRTIGHT

CLEANOUT DOOR

SHEATHING

CEILING JOIST

COMBUSTIBLE WALL

1" (25mm)

CLEARANCE

FIRECLAY FLUE LINER

WITH AIR SPACE

EAVE

1" (25mm)

CLEARANCE

WITH FIRESTOP

RAFTER

FLASHING

CONCRETE CAP

For the method of installation to a masonry chimney shown in

Figures 13A & 13B, (page 13) it will be necessary to purchase

a 12 inch (305mm) long 8 inch (203mm) inside diametert, section of prefabricated listed solid pack chimney to use as a

thimble. Purchase a wall spacer, trim collar, and a wall band manufactured to fit the chimney section you purchase.
The safety features of this system are two fold: 1) a 2 inch (51mm) air space between the chimney section and combustible

wall; and, 2) the 1 inch (25mm) air space around the chimney connector as it passes through the chimney section to the

chimney.
The location of the opening through the wall to the chimney must leave a minimum 18 inches (457mm) vertical clearance

between the connector pipe and the ceiling to prevent the ceiling from catching fire.
Measure as shown in

Figure 12A. Cut an opening in the wall large enough to accommodate the outside dimension of the

chimney section plus the minimum air space specified by its manufacturer. It may be necessary to cut the wall studs and

install a header and a sill frame to maintain the wall support. The hole in the chimney must have at least an 8 inch (203mm)

diameter fire clay liner or equivalent, secured with refractory mortar. If it is necessary to cut a hole in the chimney liner, use

extreme care to keep it from shattering.

WARNING! ALWAYS FOLLOW CHIMNEY CONNECTOR MANUFACTURER’S INSTRUCTIONS FOR PROPER INSTALLATION.

CHIMNEY CONNECTOR IS TO BE USED ONLY WITHIN THE ROOM, BETWEEN THE STOVE AND CEILING OR WALL, NEVER

PASSING THROUGH A COMBUSTIBLE CEILING OR WALL. THE CONNECTOR SHALL NOT PASS THROUGH AN ATTIC OR

ROOF SPACE, CLOSET OR SIMILAR CONCEALED SPACE, OR A FLOOR, OR CEILING. MAINTAIN MINIMUM CLEARANCES

TO COMBUSTIBLES AS REFERENCED ON PAGES 6 & 7.