Isle royale wood stove, Floor protection, 8" usa – Hearth and Home Technologies 823-0170 User Manual

Page 7

Advertising
background image

Page 7

Isle Royale Wood Stove

R

September 1, 2008

250-5763C

FLOOR PROTECTION

The floor must be non-combustible material, extending beneath heater and to the front, sides and rear as indicated. The

floor must be non-combustible or otherwise adequately protected from radiant heat given off by the unit and from sparks

and falling embers. A layer of thin brick or ceramic tile over a combustible floor is not sufficient. See Alternate floor protec-

tion calculation sample on

page 8.

In USA installations, it is necessary to install a floor protector 16 inches in front and 8 inches to both sides of the loading

door.

See *exception below.

In Canada, similar floor protection must be provided 18 inches (457mm) in front and 8 inches (203mm) from the sides and

rear of the stove.

See *exception below.

*ExCEPTION: Non combustile floor protections must extend beneath the flue pipe when installed with horizontal venting

and extend 2 inches (51mm) beyond each side.

CANADA

203mm (8")

203mm

(8")

203mm

(8")

457mm (18")

1251mm

(49-1/4")

Minimum

1137mm (44-3/4")

Minimum

16" from glass - std legs

8"

USA

Fuel loading door

36-3/4"

Minimum

39-1/4"

Minimum

must extend

length of flue and

2" (51mm)

beyond each

side of pipe

USA - Required

CANADA - Recommended

16"

optional coverage

optional

coverage

optional

coverage

8”

36-9/16"

required

coverage

38-5/8"

51"

30-3/8"

51"

USA Installations

fuel loading door