Isle Royale Wood Stove

R

September 1, 2008

250-5763C

REVERSIBLE FLUE COLLAR

The flue collar is reversible for either a top or rear venting

installation. The unit is shipped with the flue collar in the top

vent position.

CONVERTING COLLAR FOR REAR VENT INSTALLATION

1. Remove 5 Phillips head screws from the rear shield, lift

shield up and set aside.

2. Remove bolts from each side of the flue transition (2

total). (Place your free hand in flue opening to locate

and retrieve nuts attached to bolts.)

3. Turn vent to horizontal position. Inspect sealant to ensure

a leak free application.

4. Re-assemble in reverse order.

Mounting Screws

Bend Flange Down

Please note this cover plate will not

work with the Low-Profile Kit

REAR FLUE DEFLECTOR COVER PLATE

This cover plate is used when the flue collar is turned for a

rear vent application.

2. Bend the cover plate flange down.
3. Secure the cover plate with the remaining two screws.

1. After the flue collar has been reversed for a rear vent

installation, install the cover plate on the stove with the

two screws provided.