Isle royale wood stove, Outside air kit installation, If necessary – Hearth and Home Technologies 823-0170 User Manual

Page 17

Advertising
background image

Page 17

Isle Royale Wood Stove

R

September 1, 2008

250-5763C

OUTSIDE AIR

TERMINATION CAP

(contains rodent screen)

FLEX FLANGE

1

. Remove all materials from packing box.

2. Mount the flex flange (with pipe fitting extending out),

over the intake air opening at the rear of stove using the

four mounting screws supplied with kit.

3. Cut a 4 inch (102mm) minimum hole in the floor or wall

to accommodate outside air piping. Use 4 inch (102mm)

metal flex or rigid piping to directly connect outside air to

the unit or into vented crawl space. (Do not put flex into

a non-vented crawl space). If using flex tubing attach

cable ties to secure tubing at both ends. Use the supplied

termination cap with a rodent screen. Seal between the

floor or wall and the pipe with silicone to prevent moisture

penetration.

Items Needed for Installation: 4 inch (102mm) diameter

flex pipe in the length as required for your installation;

Phillips screwdriver; Silicone sealant; Drills and saws

necessary for cutting holes through the wall or flooring

in your home.

Included in Kit: 1 flex flange; 2 cable ties; oustide air

termination cap; mounting screws (Discard the remaining

parts).

OUTSIDE AIR KIT INSTALLATION

NOTE: If you plan to install the optional blower and the

outside air kit, complete installation of the outside

air kit first.

1. Remove 3 Phillips head screws from rear of unit.
2. Using the Phillips head screws, attach blower to lower rear

of stove, as shown.

3. Plug blower cord into a grounded outlet. Do not remove

ground prong from plug. Route power cord to avoid heat

from the stove, or other damage. Do not route cord under

or in front of appliance.

4. Adjust the blower speed control to the desired speed.

INSTALLATION OF OPTIONAL BLOWER

The blower is shipped fully assembled and ready for installation.

ADJUSTING THE BLOWER SPEED CONTROL,*

If Necessary

NOTE: When the speed control is turned clockwise, it will click on

to high speed. Turn the speed control clockwise to decrease

the speed. At full clockwise, the blower should blow gently,

but should not stop.

1. With the unit plugged in, turn the speed control knob to slow

(full clockwise).

2. With a small screwdriver, adjust the blower speed by turning

the adjustment mechanism through the hole on the side of

the speed control.

3. Adjust the speed so the blower runs slowly, but does not stop.

Turn clockwise to slow the blower and counterclockwise to

increase the speed.

*The blower speed control for this unit is adjusted at the factory,

and normally does not require further adjustment.

Rear Shield

Blower Mounting

Flange

Blower Speed Control

Blower

Mounting

Flange

Rear

Shield

Advertising