Table 5. Installer Self-Test Options.

NOTE:

Press any key and the displayed numbers will change. Press Time

▼

▼

to go to the previous test and Time

▲

▲

to

go to the next test. The Run Program Key will not exit this test. Press Time

▲

▲

or Time

▼

▼

and then the Run

Program Key to exit.

Key to

Press

Test

Number

Description

Heating Equipment Self-Test

Time

▲

10

Enter heating equipment self-test.

▲

11

Stage-one heat comes on. The system fan is also energized.

▲

12

Stage-two heat comes on. Stage-one heat and system fan remain on.

▼

11

Stage-two heat turns off.

▼

10

Stage-one heat and system fan turn off.

Cooling Equipment Self-Test

Time

▲

30

Change from heating to cooling equipment self-test.

▲

31

Stage-one cool and system fan come on.

▲

32

Stage-two cool comes on. Stage-one cool and system fan remain on.

▼

31

Stage-two cool turns off.

▼

30

Stage-one cool and system fan turn off.

Fan Equipment Self-Test

Time

▲

40

Change from cooling to fan equipment self-test.

▲

41

Fan comes on.

▼

40

Fan turns off.

Key Operation Self-Test

Time

▲

60 2