3. volt-ampere curves, 4. selecting a location – Hobart Welding Products STICKMATE OM-949 User Manual

Page 14

Advertising
background image

OM-949 Page 10

215 257-A

The volt-ampere curves show the

minimum and maximum voltage

and amperage output capabilities.

Curves of other settings fall be-

tween the curves shown.

3-3. Volt-Ampere Curves

Max

Rated Load

Min

Amps

Volts

80

70

60

50

40

30

20

10

0

25

50

75

100

125 150 175

200 225

230 Volt Model

3-4. Selecting A Location

804 294-A

1

Rating Label

Locate unit near correct input

power.
Y Special installation may be

required where gasoline or

volatile liquids are present −

see NEC Article 511 or CEC

Section 20.

18 in (457 mm) for airflow

1