1 – Quick Reference

13

Front Panel Menus - At a Glance

ADDRESS 7

Sets the HP-IB Address

INTF HPIB

Selects an interface (HPIB or RS232)

BAUDRATE 300

Selects baud rate (300, 600, 1200, 2400, 4800, 9600)

PARITY NONE

Selects message parity (NONE, EVEN, ODD, MARK, SPACE)

FLOW NONE

Selects flow control (XON-XOFF, RTS-CTS, DTR-DSR, NONE)

LANG SCPI

Selects language (SCPI or COMP)

*RCL 0

Recalls instrument state

*SAV 0

Saves present instrument state

ERROR 0

Displays errors in SCPI error queue

12.000V 0.204A

Measures output voltage and current

12.500V MAX

Measures peak output voltage

1

1.000V MIN

Measures minimum output voltage

1

12.330V HIGH

Measures the high level of a voltage pulse waveform

1

0.080V LOW

Measures the low level of a voltage pulse waveform

1

12.000V RMS

Measures rms voltage

1

0.350A MAX

Measures peak output current

1

0.050A MIN

Measures minimum output current

1

0.400A HIGH

Measures the high level of a current pulse waveform

1

0.012A LOW

Measures the low level of a current pulse waveform

1

0.210A RMS

Measures rms current

1

VOLT 20.000

Sets the output voltage

CURR 2.000

Sets the output current

OC -- -- -- --

Protection status (example shows overcurrent tripped)

*RST

Places the dc source in the factory-default state

PON:STATE RST

Select the power-on state command (RST or RCL0)

PROT:DLY 0.08

Sets the output protection delay in seconds

RI LATCHING

Sets the remote inhibit mode (LATCHING, LIVE, or OFF)

DFI OFF

Sets the discrete fault indicator state (ON or OFF)

DFI:SOUR OFF

Selects the DFI source (QUES, OPER, ESB, RQS, or OFF)

PORT RIDFI

Sets the output port functions (RIDFI or DIGIO)

DIGIO 7

Sets and reads the I/O port value (0 through 7)

RELAY ON

Sets the output relay state (ON or OFF)

2

RELAY NORM

Sets the output relay polarity (NORM or REV)

2

VOLT:PROT 22

Sets overvoltage protection level

CURR:RANG HIGH

Sets current range (HIGH, LOW, or AUTO)

CURR:DET ACDC

Sets current measurement detector (ACDC or DC)

1

CAL ON

Accesses calibration menu (See User’s Guide).

Use and to select menu parameters. Use to exit any menu and return to metering mode.

1

Not available on HP 6631B - 6634B or in Compatibility mode.

2

Not available on HP 6631B.

Address

Recall

Save

Shift

Error

Shift

Meter

Voltage

Current

Protect

Output

OV

Shift

Shift

Input

Cal

Shift

Meter

г

д