HP XU800 User Manual

Page 122

Advertising
background image

122

6 Tests and Error Messages

Order in Which POST Tests Are Performed

A2h

Displaying any soft key errors.

A3h

Soft error display has completed; Setting the keyboard typematic rate.

A4h

Keyboard typematic rate is set. Programming the memory wait states.

A5h

Memory wait state programming is over. Clearing the screen and enabling parity and the
NMI.

A7h

NMI and parity enabled. Performing any initialization required before passing control to the
adaptor ROM at E000h.

A8h

Initialization before passing control to the adaptor ROM at E000h

A9h

Returned from adaptor ROM at E000h control. Performing any initialization required after
the E000h option ROM had control.

AAh

INitialization after E000h option ROM control has completed. Displaying the system
configuration.

ABh

Building the multi-processor table, if necessary.

ACh

Uncompressing the DMI table data and initializing DMI POST.

B0h

System configuration is displayed.

B1h

Copying any code to specific areas.

00h

Code copying to specific area is done. Passing control to INT 19h boot loader.

Checkpoint

Code

POST Routine Description (Continued)

(A Check Point Code is NOT an error code or error number)