Parallel

Interface Modes

5-27

Additional Technical Information

Parallel Interface Modes

In addition to Centronics parallel communication, your printer’s paral-
lel interface provides IEEE 1284 bidirectional parallel communication,
which supports five modes of operation. The printer automatically rec-
ognizes and uses the mode dictated by the host.

Byte Mode

Printer-host communication is done in bytes.The byte mode may be
used by the host device in a DMA (Direct Memory Access) mode for
more efficient operation.

When byte transfer is complete and there is no more data to transmit,
the host may do one of the following:

n

Terminate and return to the compatibility mode.

n

Stay in the Host Busy, Data Not Available phase.

n

Set Host Busy Low, putting the interface into the idle phase.

If there is additional data, the host may do one of the following:

n

Set Host Busy Low, indicating that the host can accept additional
data.

n

Stay in the Host Busy, Data Not Available phase.

n

Terminate and return to the compatibility mode.

Check your host documentation to see if the host is IEEE 1284 com-
patible.

Compatibility Mode

Printer-host communication is done in a manner that ensures com-
patibility.