background image

11

U8AA5540012

4. CONTROL BOX

[1] Switching Regulator

Supplies power to start the Programmable Controller, etc.

[2] Noise Board

Board to remove noise in the unit.

[3] Current Sensor

Reads amperage in the Electrolytic Cell.

[4] Water Level Sensor Board

Board to control the Water Level Sensor.

[5] Operation Board

Board with switches to operate the Control Panel, etc.

[6] Magnetic Contactor

Switches polarity of the Electrolytic Cell.

[7] Relay 1

For [10] DC Power Supply.

[8] Relay 2

Controls the water level in the Water Tank.

[9] Relay 3

Switches the electrolyzed water display of the Remote Controller.

[10] DC Power Supply

Power supply for cells to generate electrolyzed water.

[11] Programmable Controller

Manages all controls of the unit.

[12] Noise Filter

Removes noise from 1. [19] Electromagnetic Metering Pump.

[13] Ferrite Core (not shown)

Removes noise in the unit.

[1]

[2]

[3]

[4]

[13]

[5]

[12]

[6]

[11]

[10]

[9]

[8]

[7]