Hoshizaki ROX-20TA-U User Manual

Page 21

Advertising
background image

19

U8AA5540012

To cancel the adjustment, press the Display Button and Flush Button together to show “A
6” in the Display Window.

6) When the Display Window shows “A 6”, keep on pushing the Set Button. Check that the

Display Window reads “AdJ.”

7) While pushing the Set Button, press the Display Button one time.
8) Check that the Display Window reads “CHE.”, which means the unit is in the check mode.
9) While pushing the Set Button, press the Display Button one more time.

10) Check that the Display Window reads “Nor.”, which means the unit is in the normal mode.
11) Release the Set Button.
12) This is the end of adjustment.

A7: Cell Running/Reverse Time Reset

1) Follow the steps 1) to 8) in “A1: Cell Lifecycle” to show “A 1” in the Display Window on the

Control Panel.

2) Push the Set Button six times to show “A 7” in the Display Window.
3) Push the Flush Button one time. The Display Window will flash “

”.

Now it is ready

to reset the cell running/reverse time.

4) To reset, press the Set Button for 10 sec. The Display Window will stop flashing “

and show “Good”, then “A 7” which means completion of the resetting. To cancel the
resetting, press the Display Button and Flush Button together to show “A 7” in the Display
Window.

5) When the Display Window shows “A 7”, keep on pushing the Set Button. Check that the

Display Window reads “AdJ.”

6) While pushing the Set Button, press the Display Button one time.
7) Check that the Display Window reads “CHE.”, which means the unit is in the check mode.
8) While pushing the Set Button, press the Display Button one more time.
9) Check that the Display Window reads “Nor.”, which means the unit is in the normal mode.

10) Release the Set Button.
11) This is the end of resetting.

A8: Initial Flush Cycle Time

1) Follow the steps 1) to 8) in “A1: Cell Lifecycle” to show “A 1” in the Display Window on the

Control Panel.

2) Push the Set Button seven times to show “A 8” in the Display Window.
3) Push the Flush Button one time. The Display Window will flash the present initial flash

cycle (factory setting: 3 s). Now it is ready for adjustment.

4) To raise the set value, push the Display Button. To lower the set value, push the Flush

Button. The Display Window will flash the changing set value. (For a rapid change, keep
on pushing the Display Button or Flush Button for more than 1 sec.)

5) To determine the set value, press the Set Button one time. The Display Window will stop

flashing and show the set value, then “A 8” which means completion of the adjustment. To
cancel the adjustment, press the Display Button and Flush Button together to show “A 8”
in the Display Window.

Advertising