23

U8AA5540012

Relay X3

Magnet Switch

Relay X1

Gear Motor

Water Valve

None

Pulse signal to
Metering Pump

Output to DC power
supply CNT-TOG

12) When the desired check item code is displayed, push the Flush Button one time. The

Display Window will show the present check item information.

13) To finish checking, press the Display Button and Flush Button together to show “C 1”, “C

2”... in the Display Window.

14) When the Display Window shows one of those check item codes, keep on pushing the

Set Button. Check that the Display Window reads “CHE.”

15) While pushing the Set Button, press the Display Button one time.
16) Check that the Display Window reads “Nor.”, which means the device is in the normal

mode.

17) Release the Set Button.
18) This is the end of checking.

C1: Output Conditions

The lighting LED shows the applicable output is ON.

C2: Input Conditions

The lighting LED shows the applicable input is ON.

Direction Microswitch

Location Microswitch

Display Button

Flow Rate Switch

Level Sensor

Flush Button

Set Button

Max. Water Level
(Float Switch ON)

None