Functions and adjustment of check items – Hoshizaki ROX-20TA-U User Manual

Page 23

Advertising
background image

21

U8AA5540012

2. FUNCTIONS AND ADJUSTMENT OF CHECK ITEMS

The water electrolyzer is provided with the ten check items of the following functions:

No.

C1

C2

C3

C4

C5

C6

C7

C8

C9

C10

Check Items

Output Conditions

Input Conditions

Present Average Amperage (A)

Present Stroke Speed (spm)

Present Cell Reverse Time (h)

Last Error Code

Last Error Cell Running Time (h)

Last Error Cell Reverse Time (m)

Last Error Average Amperage (A)

Last Error Stroke Speed (spm)

Functions

Displays all the present output conditions in the
Display Window on the Control Panel.

Displays all the present input conditions in the
Display Window on the Control Panel.

Displays the average amperage at present.

Displays the stroke speed at present.

Displays the cell reverse time at present.

Displays the error code of the last error.

Displays the cell running time of the last error.

Displays the cell reverse time of the last error.

Displays the average amperage of the last error.

Displays the stroke speed of the last error.

CHECKING PROCEDURE

1) Run the electrolyzer to dispense electrolyzed water or to turn on the Add Salt Water Lamp

or the Service Call Lamp.

2) Open the Door.
3) The Display Window on the Control Panel shows the present cell lifecycle, amperage (A)

or voltage (V), or an error code. Keep on pushing the Set Button.

4) Check that the Display Window reads “Nor.”, which means the unit is in the normal mode.

Lighting

Lighting

Advertising