Heatilator • A36C & A42C • 28396 Rev Y • 10/06

23

2 in. (51 mm) min.

4-1/2 in.

(114 mm)

max.

1-1/2 in.

(38 mm) min.

overlap

Cap Standoff

Top of Pipe

Flashing Collar

Figure 6.7 Installing an ST375 Square Termination Cap

Top of Pipe

2 in.

(51 mm)

min.

Flashing

Collar

1-1/2 in.

(38 mm)

min.

overlap

3 in.

(76 mm)

max.

Figure 6.8 Installing a TS345/TS345P Square Termination Cap

The last section of pipe
must stop between the
distances given below.

2 in. (51 mm) above top

of the chase.

7 in. (178 mm) below top

of the chase.

{

Top of Pipe

1-1/2 in. (38 mm)
min. overlap

Figure 6.9 Installing a TCT375 Terra Cotta Cap

For installations utilizing an ST375 Square Termination

Cap the last chimney section must not be more than
4-1/2 in. (114 mm) below the chase top. See Figure 6.7.

For installations utilizing a TS345/TS345P Square

Termination Cap, the uppermost chimney section must
not be more than 3 in. (76 mm) below the chase top. See
Figure 6.8

For installations utilizing an TCT375 Terra Cotta Cap the last

chimney section must be between 7 in. (178 mm) below
the chase top and 2 in. (51 mm) above. See Figure 6.9.

For chase installations you can use a TR344 Round

Termination Cap, a TR342 Round Telescoping Termination
Cap, an ST375, TS345 or TS345P Square Termination
Cap, or a TCT375 Terra Cotta Termination Cap.

For installations utilizing a European Copper Series

Termination Cap, See Figure 6.10.

Install termination caps following instructions provided

with them.

chimney top

2 - 6 in.

(51-152 mm)

2 in. (51 mm)
typical

chase

top

(metal or masonry)

Cap Base

(cap inner flue)

SL pipe

inner flue

screw (8)*

bracket (8)

Figure 6.10 Installing a European Copper Series Termination Cap

(CT3-King shown)