Hearth and Home Technologies A42CH EN User Manual

Page 43

Advertising
background image

Heatilator • A36C & A42C • 28396 Rev Y • 10/06

43

Woodburning Termination Cap

Shroud

TS345 / 445

(Top Vent)

TR342 / 344
TR442 / 444

TR342 / 344 TV
TR442 / 444 TV

(with TR-TVK installed)

TR11 / 11T

TR11 / 11T TV

(with TR-TVK installed)

OPEN TOP with solid sides and 3 in. opening at the bottom.

Minimum Base Dimensions

(Inches)

23 X 23

28 X 28 with

Radiation Shield

26 X 26

32 X 32 with

Radiation

Shield

26 x 26

Minimum Top Dimensions

(Inches)

20 x 20

25 X 25

23 X 23

29 X 29

23 x 23

MAILBOX STYLE with open ends and 3 inch opening at the bottom of the sides.

Minimum Base Dimensions

(Inches)

N/A

26.5 X 28 with

Radiation Shield

28 X 30

34 X 34 with

Radiation

Shield

28 X 30 with

Radiation Shield or

34 X 34

Minimum Height (Inches)

N/A

28 1/4

27 1/2

28 1/4

27 1/2

ROOFED STYLE with 12 X 22 (264 sq. in.) opening on each side and 3 in. space between the
radiation shield and chase top.

Minimum Base Dimensions

(Inches)

N/A

27 X 27 with

Radiation Shield

27 X 27 with

Radiation Shield

34 X 34 with

Radiation

Shield

34 X 34 with

Radiation Shield

Minimum Height (Inches)

N/A

23

23

23

23

Minimum Height is measured from the bottom of the termination cap:

Minimum height is established with the bottom of the termination cap 7 in. above the chase top. Minimum height must increase
accordingly for any height above 7 in.