HP OMNIBER 718 HP 37718A User Manual

Page 118

Advertising
background image

108

Storing, Logging and Printing

Logging Results

Optional Internal printer fitted into the instrument front cover
(Option 602)

External HP-IB printer (option 601)

External RS-232-C printer (option 601)

External Parallel Port printer (option 601)

Disk Drive

HOW TO:

1

Choose LOGGING [ON] - enables the logging of results and alarms.

2

Choose LOGGING PERIOD - determines how regularly the results
and alarms are logged.
USER PROGRAM provides a choice of 10 minutes to 99 hours.

3

Choose RESULT LOGGED - allows you to log all results to or choose
only those results you require.

4

Choose WHEN - allows you to choose to only log when the error count
for the logging period is greater than 0. If the error count is 0 then the
message NO BIT ERRORS is displayed.

5

Choose CONTENT - allows you a choice of error results to be logged.
Error Results, Analysis or Error and Analysis (ER & ANAL)
and
Period, Cumulative or Period and Cumulative (PER & CUMUL).

6

If LOG ERROR SECONDS [ON] is chosen a timed and dated message
is logged each time an error second occurs (excessive occurrences of
error seconds during the logging period will result in heavy use of

Advertising