Firmware errors, System board faults, Fan faults – HP AD117-9003A-ED3 User Manual

Page 107: Processor faults

Advertising
background image

Table 5-15 Firmware Errors

Solution

Problem

LED 4

LED 3

LED 2

LED 1

System LED

View the SEL for additional
information.

System
firmware hang

OFF

OFF

RED

OFF

Flashing
Red

Table 5-16 System Board Faults

Solution

Problem

LED 4

LED 3

LED 2

LED 1

System LED

View the SEL for additional
information. For further assistance,
contact your HP Support Engineer.

VRM
overvoltage

OFF

RED

GREEN

OFF

Flashing
Red

View the SEL for additional
information. For further assistance,
contact your HP Support Engineer.

VRM
undervoltage

OFF

RED

OFF

GREEN

Flashing
Red

Table 5-17 Fan Faults

Solution

Problem

LED 4

LED 3

LED 2

LED 1

System LED

Replace the fan that is not
functioning.

Fan 1A fault

RED

OFF

OFF

GREEN

Flashing red

Replace the fan that is not
functioning.

Fan 1B fault

RED

OFF

GREEN

OFF

Flashing red

Replace the fan that is not
functioning.

CPU 0-Fan
fault

RED

GREEN

OFF

OFF

Flashing red

Replace the fan that is not
functioning.

CPU 1-Fan
fault

RED

OFF

GREEN

GREEN

Flashing red

Replace the fan that is not
functioning.

Fan 2
(memory)
fault (both
rotors)

RED

GREEN

GREEN

OFF

Flashing red

Replace the fan that is not
functioning.

Fan 3
(disks/PCI)
fault (both
rotors)

RED

GREEN

GREEN

GREEN

Flashing red

Table 5-18 Processor Faults

Solution

Problem

LED 4

LED 3

LED 2

LED 1

System LED

Make sure nothing is blocking the
server’s airflow and locate your server
in an air-conditioned room. In a single
CPU configuration, verify that the
airflow blocker is installed.

Processor 0
temperature
exceeds limit

OFF

GREEN

RED

RED

Flashing
Red

Processor 1
temperature
exceeds limit

GREEN

OFF

RED

RED

Flashing
Red

Verify that the processor or processors
are correctly installed.

No processor
detected

GREEN

GREEN

RED

RED

Flashing
Red

Identifying and Diagnosing Hardware Issues