7. selecting weld cable sizes, 8. remote 14 receptacle information – Hobart Welding Products ARCSTAR 280 NT User Manual

Page 20

Advertising
background image

OM-4402 Page 16

4-7.

Selecting Weld Cable Sizes

Total Cable (Copper) Length In Weld Circuit Not Exceeding

Welding

Amperes

100 ft (30 m) Or Less

150 ft

(45 m)

200 ft

(60 m)

250 ft

(70 m)

300 ft

(90 m)

350 ft

(105 m)

400 ft

(120 m)

Amperes

10 – 60%

Duty Cycle

60 – 100% Duty

Cycle

10 – 100% Duty Cycle

100

4

4

4

3

2

1

1/0

1/0

150

3

3

2

1

1/0

2/0

3/0

3/0

200

3

2

1

1/0

2/0

3/0

4/0

4/0

250

2

1

1/0

2/0

3/0

4/0

2-2/0

2-2/0

300

1

1/0

2/0

3/0

4/0

2-2/0

2-3/0

2-3/0

350

1/0

2/0

3/0

4/0

2-2/0

2-3/0

2-3/0

2-4/0

*Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere. Contact your
distributor for the mm

2

equivalent weld cable sizes.

S-0007-E

4-8.

Remote 14 Receptacle Information

Engine runs at weld/power speed whenever a device connected to the remote 14
receptacle is running.

NOTE

Socket*

Socket Information

24 VOLTS AC

A

24 volts ac.

A

J

B

K

I

L

24 VOLTS AC

B

Contact closure to A completes 24 volt ac contac-
tor control circuit. Protected by circuit breaker
CB5.

C

L

N

H

D

M

G

115 VOLTS AC

I

115 volts ac.

D

M

G

E

F

115 VOLTS AC

J

Contact closure to I completes 115 volt ac contac-
tor control circuit. Protected by circuit breaker
CB6.

A/V

C

0 to +10 volts dc output to remote control.

A/V

AMPERAGE

D

Remote control circuit common.

AMPERAGE

VOLTAGE

E

0 to +10 volts dc input command signal from
remote control.

GND

G

Circuit common for 24 and 115 volt ac circuits.

801 943-B

GND

K

Chassis common.

*The remaining sockets are not used.