OM-4402 Page 17

4-9.

Adjusting MIG Weld Puddle Consistency

801 944-C / Ref. 198 912

Y

Stop engine.

Stabilizer DC-Z is factory
connected to suit most MIG (Wire
Welding) applications.

To change MIG weld puddle consis-
tency, proceed as follows:

Remove lower front panel and side
panel.

Starting from center of DC-Z, the
three leads 79 will be referred to as
inner, middle, and outer.

1

Stabilizer DC-Z

2

Inner Lead 79

3

Middle Lead 79

4

Outer Lead 79

5

Wire (CV) Weld Output
Terminal

Middle lead 79 is connected to Wire
(CV) weld terminal at the factory.
Disconnect middle lead 79 from
terminal.

To wet out weld puddle:

Remove insulation sleeve from in-
ner lead 79. Connect inner lead 79
to Wire (CV) terminal, reusing
hardware.

To stiffen weld puddle:

Remove insulation sleeve from out-
er lead 79. Connect outer lead 79 to
Wire (CV) terminal, reusing
hardware.

Slide sleeves over unused leads 79,
and secure with cable ties. Reinstall
panels.