1. routine maintenance, 20 h 25 h, 50 h – Hobart Welding Products ARCSTAR 280 NT User Manual

Page 26: 100 h, 200 h, 500 h, 1000 h

Advertising
background image

OM-4402 Page 22

SECTION 7 – MAINTENANCE AND TROUBLESHOOTING

7-1.

Routine Maintenance

Recycle

engine

fluids.

Y

Stop engine before maintaining.

.

See Engine Manual and Maintenance Label. Ser-
vice more often if used in severe conditions.

*

To be done by Factory Authorized Service Agent.

8 h

Wipe up spills.

Check fluid levels.
See Section 4-2.

OIL
Full

20 h

25 h

Check and clean
spark arrestor screen.
See Section 7-4.

Service air filter wrapper
(foam element). See
Section 7-3.

50 h

Clean and
tighten weld
terminals.

Clean cooling system. See
engine manual.

100 h

Change oil. See
Section 7-5 and
maintenance
label.

Change oil filter.
See Section 7-5
and maintenance
label.

Clean and
tighten battery
connections.

Service air filter element.
See Section 7-3.

200 h

Check valve
clearance.*

Replace fuel
filter. See
Section 7-5.

Replace
unreadable
labels.

Check spark plugs.

500 h

Repair or
replace cracked
cables.

Service welding generator
brushes and slip rings.
Service more often in dirty
conditions.*

1000 h

Blow out or
vacuum inside.
During heavy
service, clean
monthly.

OR

Clean crankcase
breather valve.

Remove cylinder
head deposits.*

Advertising