Final installation check requirements, Confirm all files up-to-date, System status – Hughes Direcway DW6000 User Manual

Page 53: 29 final installation check requirements

Advertising
background image

Chapter 2 • Installing the indoor equipment

1033295-0001 Revision 2

29

Final installation check
requirements

• Confirm that

Software Download Status

in the User Interface

System Status

screen shows "All files are up-to-date."

• Connect the customer computer to the DW6000 and confirm

the customer can surf to at least the myDIRECWAY.com site
or another Internet site after the

Software Download Status

shows "All files are up-to-date."

• Help the customer download the DW6000 User Guide from

myDIRECWAY.com. The customer must register with
myDIRECWAY.com to download the User Guide.

• Confirm the user’s

System Information

page has been

printed out and the site ID, Gateway IP address, and subnet
mask recorded in the Quick Start Guide.

• Help the customer create a browser shortcut to the System

Control Center. If necessary rename the shortcut "System
Control Center."

Confirm all files up-to-date

1. Type

www.direcwaysupport.com

(or 192.168.0.1) in the

location bar and press E

NTER

. The

Control Center

appears. I

2. Click on the

System Status

button. The

System Status

screen appears. See Figure 34.

3. Check the

Software Download Status

line message. If it reads

"All files are up-to-date" the unit has been commissioned.

If "All files up-to-date" does not appear, wait a few minutes.
If the message still does not appear, power cycle the unit by
unplugging it from the power source and plugging it back in
and wait 15 minutes. If the message still does not appear,
contact installer support,

Figure 33: System Status