Startup, Warning – Hitachi 231580 User Manual

Page 10

Advertising
background image

10 308715

Startup

WARNING

FIRE AND EXPLOSION HAZARD

To reduce the risk of static sparking and

splashing when priming or flushing the

system, hold a metal part of the gun

firmly to the side of a grounded metal pail before

triggering the gun.

7.

To prime the hose, lower the pressure to reduce

splashing. Hold a metal part of the gun firmly

against and aimed into a grounded metal pail.

See

the preceding WARNING. Hold the gun trigger

open and slowly increase the pressure until the

pump starts. Keep the gun triggered until all air is

forced out of the system and the fluid flows freely

from the gun. Release the trigger and engage the

gun safety latch.

8.

Check all fluid connections for leaks . Relieve

pressure before tightening the connections.

9. Engage the gun safety latch.

10.

Install the spray tip and tip guard. Install the

spray tip. If you are using the RAC IV tip guard,

refer to manual 308644 for installation instructions.

11.

Adjust the spray pattern
a. Increase the pressure until spray from the gun

is completely atomized. To avoid excessive

overspray and fogging, and to extend tip and

sprayer life, always use the lowest pressure

needed to get the desired results.

b. If more coverage is needed, use a larger tip

rather than increasing the pressure.

c. Adjust the direction of the spray pattern. See

Fig. 9. Engage the gun safety latch. Loosen

the retaining nut (A). Position the tip guard for

a horizontal or vertical pattern. Hold the tip

guard in place and tighten the retaining nut.

NOTE: Spray patterns will change as tips wear.

Change the spray tip if adjusting the pressure will not

improve the spray pattern.

Fig. 9

For a horizontal

spray pattern

For a vertical

spray pattern

1

2

2

A

05971

1

Advertising