Shutdown and Care

WARNING

INJECTION HAZARD

To reduce the risk of serious injury,

whenever you are instructed to relieve

pressure, follow the

Pressure Relief

Procedure on page 9.

Shutdown and Care

1.

Check the packing nut/wet-cup daily (102).

Relieve pressure first. Keep the wet-cup 1/3 full of

TSL at all times to help prevent fluid buildup on the

piston rod and premature wear of packings.

2.

Tighten the packing nut/wet-cup (102) just

enough to stop leakage. Over-tightening causes

binding and excessive packing wear. Use a round

punch or brass rod and a light hammer to adjust

the nut. See Fig.10.

3.

Periodically clean paint residue from the pres-

sure transducer (29) vent hole area. See Fig. 11.

Replace the transducer when leakage is exces-

sive. See page 27.

4.

Lubricate the bearing housing after every 100

hours of operation. Remove the front cover. Fill the

bearing housing cavity (A) with SAE 10 non-

detergent oil. See Fig. 11.

5.

Flush the sprayer at the end of each work day

and fill it with mineral spirits to help prevent pump

corrosion and freezing. See page 12.

CAUTION

To prevent pump corrosion, and to reduce the chance

of fluid freezing in the pump in cold weather, never

leave water or any type of paint in the sprayer when it

is not in use. Freezing can seriously damage the

sprayer or result in a loss of pressure or stalling.

6.

For very short shutoff periods, leave the suction

tube in the paint, relieve pressure, and clean the

spray tip.

7.

Coil the hose and hang it on a hose rack when

storing it, even for overnight, to help protect the

hose from kinking, abrasion, coupling damage, etc.

WARNING

INJECTION HAZARD

See the warning section

INJECTION

HAZARD on page 3 for information on

the hazard of using damaged hoses.

Fig. 10

Turn packing

nut clockwise to

tighten

1

1

102

04650

Fig. 11

1

Vent hole

29

A

1

04651

Advertising