7

Setup

Grounding

WARNING

Improper installation or alteration of the grounding

plug will result in a risk of electric shock, fire or

explosion that could cause serious injury or death.

1. This equipment requires a 120 Vac, 60 Hz, 15A

circuit with a grounding receptacle. See Fig. 3.

Fig. 3

Grounding Prong

Grounded

Outlets

2. Do not alter the ground prong or use an adapter.

3. A 12 AWG gauge, 50 ft extension cord may be

used with this equipment.

Operation

How to use the gun trigger safety

When engaged, the gun safety latch prevents the gun

from accidental triggering. See Fig. 4.

WARNING

INJECTION HAZARD

If the gun still sprays when the gun

trigger safety is locked, repair the gun.

See manual 308645, supplied.

Fig. 4

1

2

Gun safety latch

shown engaged

2

Gun safety latch

shown disengaged

05964

1

How to use the pressure drain valve.

Use the pressure drain valve to relieve fluid pressure

from the pump and to help prime the pump. If the valve

senses an over pressure condition, it opens automati-

cally to relieve fluid pressure. If this happens, stop

spraying immediately, shut off and unplug the sprayer.

Determine the cause of the problem and correct it

before operating the sprayer again. Refer also to the

Troubleshooting, page 13. See Fig. 5.

Closed, or spray position

Open or drain, position

Fig. 5

1
2

1

2

04646

How to use the pressure control.

The pressure control controls the motor operation so

the sprayer maintains constant fluid pressure at the

pump outlet. Turn the pressure control knob fully

counterclockwise to obtain the minimum setting. Turn

the knob clockwise to increase pressure. See Fig. 6.

02824A

Fig. 6

Advertising